DS-69A Drill Stop: Prevents cutting of rebar
and conduit.
Features
-
The DS-69A prevents accidental cutting of
reinforcing bar and conduit by turning off power to the drilling unit when
grounded metal is encountered.
-
The DS-69A provides operator safety. The job
of detecting concealed rebar and conduit necessitates electrical isolation
of the drilling unit from its conventional grounding connection. The DS-69A
provides fast and reliable solid state switching to reestablish the ground
connection in cases where an external, energized line is encountered or
where the drill motor is shorted to the drill case.
-
The DS-69A may be used in a concealed metal
detect "Off" mode.

The DS-69A Drill Stop is intended primarily
to sense the presence of grounded metal in concrete and prevent damage
to this metal by terminating power to the drill motor when it is detected.
Since this function necessitates electrical isolation of the drill bit,
tool casing and tool ground line, additional switching circuitry is needed
to provide operator safety in cases where leakage current from the motor
may be present or where energized lines may be encountered during the drilling
operation. The DS-69A provides this protection by switching voltage potentials
in excess of 10 volts to a low impedance, high current capacity ground
path. This switching is accomplished in a maximum of 5 microseconds. Voltages
of up to 600V and currents of up to 110 Amps RMS continuous (1000 Amps
peak one cycle, nonrepetitive surge current) are switched to ground. Voltages
and currents in excess of these values will also be switched to ground
but may result in failure of the switching circuitry in the closed (conducting
to ground) condition. Such failure will preclude resetting of the unit
for continued operation. Information regarding the upper bound current
conducting capacity of the switching circuitry in a failed (conducting
to ground) condition is unavailable.
The DS-69A may also be operated in a concealed
metal detect "Off" mode, i.e. the drill unit will contunue to opertate
after grounded metal has been detected.
|